TCM-2000 |
TCM-2005 |
TCM-2006 |
TCM-2008 |
TCM-2100 |

| 
| 
| 
| 
|
| Manufactured at ISO 9001 Facility | Yes | Yes | Yes | Yes | Yes |
| 1-Year Warranty (parts and labor) | Yes | Yes | Yes | Yes | Yes |
| Factory Tested and Burned In | Yes | Yes | Yes | Yes | Yes |
| Weight (lbs.) | 0.89 | 2.94 | 2.86 | 2.86 | 0.87 |
| Dimensions (approx. L x W x H inches) | 6 x 4.25 x 1.75 | 7.25 x 7.3 x 2.25 | 7.25 x 7.3 x 2.25 | 7.25 x 7.3 x 2.25 | 5 x 6.125 x 1.5 |
| Case Material & Finish | Extruded Aluminum Blue Anodize | Machined Billet Aluminum Black Anodize | Machined Billet Aluminum Black Anodize | Machined Billet Aluminum Black Anodize | Extruded Aluminum |
| Voltage Range | 8 – 27 VDC | 8 – 27 VDC | 8 – 27 VDC | 8 – 18 VDC | 8 – 18 VDC |
| Current (device only, not including outputs) | On: 100 mA Quiescent: 0 mA | On: 100 mA Quiescent: 0 mA | On: 100 mA Quiescent: 0 mA | On: 200 mA Quiescent: 0 mA | On: 100 mA Quiescent: 9 mA |
| Operating Temperature | -40 to 125°C | -40 to 125°C | -40 to 125°C | -40 to 125°C | -40 to 125°C |
| Storage Temperature | -40 to 125°C | -40 to 125°C | -40 to 125°C | -40 to 125°C | -55 to 125°C |
| Reverse & Transient Voltage Protection | Yes | Yes | Yes | Yes | Yes |
| Ingress Protection | IP62 | IP67 | IP61 | IP61 | IP50 |
| Harness Interface | 63-pin CPC | 37-pin Mil spec 6-pin Mil spec *6-pin is comm only not required for operation | 37-pin CPC 16-pin CPC | 37-pin CPC 16-pin CPC | Delphi 56-pin |
| EMI Immunity | All modules are designed for robust EMI immunity. PCS offers certification testing for the desired controller/transmission package as a cost option. |
| CAN 2.0b | Yes | Yes | Yes | Yes | Yes |
| RS-232 | Yes | Yes | Yes | Yes | Yes |
| Real-time tuning and data logging with a PC | Yes | Yes | Yes | Yes | Yes |
| Real-time tuning and data logging with PCS hand-held touchscreen interface | Yes | Yes | Yes | Yes | Yes |
| In-Field Flash Upgradeable | Yes | Yes | Yes | Yes | Yes |
| Native Communication with PCS Devices | Yes | Yes | Yes | Yes | Yes |
| GM ALDL | No | No | No | No | Yes |
| Frequency (Range 0 – 10 kHz) | 4 | 4 | 4 | 4 | 3 |
| Programmable Trigger Levels and Filtering for Frequency Inputs | Yes | Yes | Yes | Yes | 2 Channels |
| Analog Voltage Inputs (0-5VDC) | 6 total 2 with 1k-ohm 5V pull-ups | 4 total 2 with 1k-ohm 5V pull-ups | 6 total 2 with 1k-ohm 5V pull-ups | 6 total 2 with 1k-ohm 5V pull-ups | 2 total 1 with 1k-ohm 5V pull-up |
| Programmable Input Parameters | Yes | Yes | Yes | Yes | Yes |
| Failure Diagnostics for each Analog Input | Yes | Yes | Yes | Yes | Yes |
| Digital Inputs (programmable active high or low) | 16 | 11 | 16 | 16 | 6 |
| Overvoltage Protection for Each Input | Yes | Yes | Yes | Yes | Yes |
| PWM Outputs | 9 | 9 | 9 | 9 | 7 |
| Digital Outputs | 3 | 2 | 3 | 3 | 1 |
| PWM & Digital Maximum Current | 3.5 Amps | 3.5 Amps | 3.5 Amps | 3.5 Amps | 3.5 Amps |
| Short Circuit, Overcurrent & Thermal Protection on each Output | Yes | Yes | Yes | Yes | Yes |
| User Selectable Output Drive Type (Battery Voltage or Ground) | Yes | Yes | Yes | Yes | Ground Only |
| Programmable Output Type/Parameter for PWM and Digital Outputs | Yes | Yes | Yes | Yes | Yes |
| Output Channel Current Monitoring | No | No | No | All 12 outputs selectable uses analog/digital inputs | 1 Dedicated high-side measured output |